used in your construction projects must meet strict regulations and quality standards.
Using the following tests CGC personnel use our state-of-the-art testing laboratories to ensure the aggregates specified for use in your projects meets or exceeds the highest quality and performance requirements established by state, national and international standards...
testing ensures the properties of asphalt mixes and finished asphalt pavements meet or exceed regulatory and quality standards.
Using the following tests CGC personnel use our state-of-the-art testing laboratories to ensure the asphalt specified for use in your projects meets or exceeds the highest quality and performance requirements established by state, national and international standards...
testing ensures the properties of concrete mixes meet or exceed regulatory and quality standards.
Using the following tests CGC personnel use our state-of-the-art testing laboratories to ensure concrete specified for use in your projects meets or exceeds the highest quality and performance requirements established by state, national and international standards...
testing ensures the properties of masonry components and assemblies meet or exceed regulatory and quality standards.
Using the following tests CGC personnel use our state-of-the-art testing laboratories to ensure masonry specified for use in your projects meets or exceeds the highest quality and performance requirements established by state, national and international standards...
investigation and testing ensures the properties of soil(s) meet or exceed regulatory and quality standards.
Using the following tests CGC personnel use our state-of-the-art testing laboratories to ensure the soil(s) to be used in your project meets or exceeds the highest quality and performance requirements established by state, national and international standards...
| Material | Test | Governing standard |
|---|---|---|
| Soil | Atterberg limits | ASTM D4318; WTM T89 and AASHTO T90 |
| Soil | Moisture content | ASTM D2216; WTM T255 for aggregate |
| Soil | Particle size analysis | ASTM D6913 (sieve), ASTM D7928 (hydrometer) |
| Soil | Moisture density curves | ASTM D698 / D1557; AASHTO T99 / T180 |
| Soil | Specific gravity | ASTM D854 |
| Soil | Organic content | ASTM D2974 |
| Soil | CBR | ASTM D1883 |
| Soil | Consolidation | ASTM D2435 |
| Soil | Constant and falling head permeability | ASTM D2434; ASTM D5084 |
| Soil | Direct shear | ASTM D3080 |
| Soil | Triaxial compression | ASTM D2850 (UU); ASTM D4767 (CU) |
| Soil | Unconfined compressive strength | ASTM D2166 |
| Soil | Relative density | ASTM D4253 / D4254 |
| Soil | Shrinkage limit and swell | ASTM D4943; ASTM D4546 |
| Aggregate | Gradation analysis | WTM T27 and T11 (AASHTO T27, T11) |
| Aggregate | LA abrasion | AASHTO T96; ASTM C131 |
| Aggregate | Crushed and uncrushed particles | WTM D5821 (ASTM D5821) |
| Aggregate | Absorption | AASHTO T85 (coarse); AASHTO T84 (fine) |
| Aggregate | Soundness and freeze-thaw | AASHTO T104; AASHTO T103 |
| Asphalt | Superpave mixture design | WisDOT standard specification 460.2.7; AASHTO R35, M323, T312 |
| Concrete | Compressive strength | WTM T22 (ASTM C39) |
| Concrete | Flexural strength | WTM T97 (ASTM C78) |
| Concrete | Diamond core drilling and testing | ASTM C42 |
| Concrete | Portland cement physical testing | ASTM C150 requirements; ASTM C109, C191 |
| Concrete | Non-destructive testing | ASTM C805, C803, C597 |
| Masonry | Brick absorption and shrinkage; compressive strength | ASTM C67 |
| Masonry | Block testing | ASTM C140 |
| Masonry | Prism tests | ASTM C1314 |
| Masonry | Mortar design and testing | ASTM C270; ASTM C780 |
| Masonry | Grout testing | ASTM C1019 |
WTM refers to a Wisconsin test method published for WisDOT work and generally parallels the AASHTO or ASTM method shown. Confirm the method and edition required by your contract or specification.
WisDOT’s 2025 Standard Specifications, section 701, require that contractor and commercial laboratories performing contract testing be qualified through the Wisconsin laboratory qualification program (opens in a new tab) and that sampling and testing be performed by technicians certified through the Highway Technician Certification Program at or above the levels in table 701-1 (section 701 (opens in a new tab)). Our Madison laboratory is accredited for HMA testing (opens in a new tab) by the AASHTO Materials Reference Laboratory and WisDOT; see our asphalt mixture design and testing page for details.
CGC performs soil tests (Atterberg limits, CBR, consolidation, permeability, direct shear, triaxial, unconfined compression, moisture density curves, particle size analysis and more), aggregate tests (gradation, LA abrasion, crushed particles, absorption, soundness and freeze-thaw), asphalt mixture design using the Superpave method, concrete tests (mix design, compressive and flexural strength, diamond core drilling, non-destructive testing and Portland cement physical testing) and masonry tests (block and brick, prisms, mortar and grout).
WisDOT's 2025 Standard Specifications, section 701, table 701-1, list WTM T11 and WTM T27 for aggregate gradation, WTM T255 for aggregate moisture content, WTM D5821 for fractured faces, WTM T89 for liquid limit and AASHTO T90 for plastic limit and plasticity index. Plastic limit testing requires GRADINGTEC-I certification and liquid limit testing requires ATTS certification.
Section 701.1.2.5 requires that contractor and commercial laboratories performing testing under a WisDOT contract be qualified through the Wisconsin laboratory qualification program. CGC's Madison laboratory is accredited for HMA testing by the AASHTO Materials Reference Laboratory (AMRL) and WisDOT.
Concrete compressive strength is tested under WTM T22 (ASTM C39) and flexural strength under WTM T97 (ASTM C78). Masonry units are tested for compressive strength and absorption under ASTM C67 or C140, and assemblages by prism testing under ASTM C1314.
CGC provides laboratory testing from its Madison and West Allis, Wisconsin offices.
Technical references last reviewed by: CSG